Pressure Transducer Calibration & Recertification Service

Factory calibration and recertification for PRESSUREPOINT pressure transducers: NIST-traceable multi-point calibration, temperature compensation, per-serial-number certificates, and a documented return-to-factory process — with calibration interval guidance for your quality system.

WHAT WE OFFER

What We Offer

NIST-Traceable Calibration

Every PRESSUREPOINT transducer is calibrated against reference standards whose calibration chain traces back to NIST. Zero, span and intermediate test points are verified across the full range, and the results are recorded per serial number.

Temperature Compensation

Zero and span are compensated across the operating temperature range during production. For applications with wide ambient swings, temperature testing is available so the certificate reflects real-site behavior rather than lab conditions alone.

Calibration Certificates

Certificates list the test points, applied pressure versus measured output, the error at each point, the reference standards used and their traceability, plus the unit’s serial number — ready for audits and quality files.

Recertification & Repair

Return your unit to the factory for recalibration: as-found testing, a full recalibration against NIST-traceable references, and repair or replacement of damaged sensing elements — with a quotation before any chargeable work starts.

Multi-Point & Hysteresis Testing

Standard five-point ascending and descending verification, or custom test points matched to your operating range, so the certificate reflects the pressures you actually measure.

Documentation Packages

Calibration certificates, test reports, material certificates and CE declarations assembled per serial number for regulated customers and ISO-style quality systems.

HOW IT WORKS

From Inquiry to Delivery

1

Request an RMA

Send the model, serial number, range, output and a short description of the issue. We confirm the service scope, price and turnaround, then issue an RMA number with shipping instructions.

2

Ship the unit

Pack the transducer with its RMA number and ship it to us. We confirm receipt and give you the inspection schedule.

3

Inspection & calibration

We run an as-found test, perform a full calibration against NIST-traceable references and check temperature behavior. If repair is needed, we send a quotation and wait for approval before work starts.

4

Certificate & return

A calibration certificate and test report are issued per serial number, and the unit is returned with tracking details. Typical turnaround is 5-7 working days after receipt.

CHALLENGES

Challenges This Service Solves

Drift between calibrations

Thermal cycling and long-term aging shift zero and span. Periodic recalibration keeps readings inside the datasheet specification and gives you documented evidence for your quality records.

Audit failures over traceability

Quality and regulated customers expect certificates that name the standards used and the traceability chain. Per-serial-number documentation removes the guesswork at audit time.

Unplanned downtime

A transducer that drifts out of spec can pass questionable data for weeks before anyone notices. Scheduled recalibration catches problems while the unit is still in service.

Temperature effects on accuracy

Uncompensated units behave differently across ambient swings. Temperature-compensated calibration and testing quantify performance in the environment where the unit actually runs.

FAQ

Pressure Transducer Calibration & Recertification Service — FAQ

How often should a pressure transducer be recalibrated?

A common starting point is a 12-month interval, which is what most ISO-style quality systems and OEM recommendations assume. Safety-critical or high-accuracy applications often use 6 months, while stable, benign installations can stretch to 24 months. The right interval for you is the one your as-found drift data supports: if consecutive certificates show small errors, you can extend it; if drift grows, shorten it.

What is included in a calibration certificate?

Test points, applied pressure and measured output at each point, the error at each point, the reference standards used with their IDs and traceability, the temperature during testing, the date, the technician and the unit’s serial number.

Is your calibration traceable to NIST?

Yes. Our reference standards are calibrated by accredited laboratories, and the chain of traceability from each standard back to NIST is documented and listed on the certificate.

How long does factory recalibration take?

Typically 5-7 working days after the unit arrives. If repair is needed, we quote the work and get your approval before starting, so additional time only accrues when you approve it.

Can you calibrate transducers from other brands?

We recalibrate PRESSUREPOINT transducers as standard. For other brands, send the model and range and we will confirm whether we can cover it — many common industrial platforms are within our test capability.

What does recalibration cost?

It depends on the range, the number of test points, temperature testing and the documentation package. We confirm the price with the RMA, before you ship anything.

RELATED SEARCHES

What Buyers Search

pressure transducer calibrationnist traceable pressure transducerpressure transmitter recalibrationpressure sensor calibration certificate4-20ma pressure transducer calibrationtemperature compensated pressure transducerpressure transducer certificate of calibrationpressure sensor recalibration servicereturn to factory pressure sensor calibrationpressure transmitter calibration interval